Magnetic Calibration Status Packet

Magnetic Calibration Status Packet
Packet ID 191
Length 3
Read / Write Read
Field # Bytes Offset Data Type Size Description
1 0 u8 1 Magnetic Calibration Status
2 1 u8 1 Magnetic calibration progress (%)
3 2 u8 1 Local magnetic error (%)

Magnetic Calibration Status Packet

Magnetic Calibration Status

Value Description
0 Magnetic calibration not completed
1 2D magnetic calibration completed
2 3D magnetic calibration completed
3 Custom values magnetic calibration completed
5 2D calibration in progress
6 3D calibration in progress
7 2D calibration error: excessive roll
8 2D calibration error: excessive pitch
9 Calibration error: sensor over range event
10 Calibration error: time-out
11 Calibration error: system error
12 Calibration error: interference error

Magnetic Calibration Status