Restore Factory Settings Packet

Note: A Factory Reset will re-enable the DHCP Client and lose any static IP address settings.

Restore Factory Settings Packet
Packet ID 4
Length 4
Read / Write Write
Field # Bytes Offset Data Type Size Description
1 0 u32 4 Verification sequence (set to 0x85429E1C)

Restore Factory Settings Packet