Hardware Specifications
Physical Dimensions - Hydrus
Physical dimensions |
484 x 264 x 216 mm |
Hydrus Physical Dimensions
Weight and Buoyancy
Weight |
6.4 kg |
Buoyancy |
+170 g in salt water (1.025 kg/L density) |
Buoyancy Control |
Fixed buoyancy |
Maximum Operating Depth
Below are the maximum operating depths of the Hydrus. It is important to adhere to these specifications to ensure safe and reliable operation. Going beyond these limits can jeopardise Hydrus, its integrity and functionality.
HYDRUS-300 |
300 m |
HYDRUS-1000 |
1000 m |
Operating Temperatures
Out of Water Temperature |
-5 °C |
50 °C |
Operating Water Temperature |
-5 °C |
35 °C
|
Storage Temperature |
-20 °C |
60 °C
|
Data Storage
Memory capacity |
256 GB (equates to more than 2 hours of survey data) |
Memory type |
Solid State Drive |
Temperature Sensor
Water Temperature Accuracy |
0.5 °C |
User Interface
E-ink (EPD) screen |
Onboard information display |
Onboard web UI (accessed via WiFi) |
Device configuration, mission planner and mission data management |