Modem Data Packet

Modem Data Packet
Packet ID 68
Length Variable, up to 255 bytes
Read / Write Read / Write
Field # Bytes Offset Data Type Size Description

1

0

u32

4

Unix Time Seconds

2

4

u32

4

Microseconds

3

8

u32

4

Serial number part 1

4

12

u32

4

Serial number part 2

5

16

u32

4

Serial number part 3

6

20

u16

2

Number of packets in sequence

7

22

u16

2

Packet sequence number

8

24

u16

2

Modem data description, see Modem Status Packet

9

26

u8

1

Data size

10

27

 

 

User data

Modem Data Packet

Modem Data Packet Information

These fields are identical to the fields in the Modem Status Packet (see Modem Status Packet). A sequence of Modem Data Packets are always preceded by a Modem Status Packet. When sending a sequence of Modem Data Packets to Subsonus, it is not required to precede the packet(s) with a Mode Status Packet.

Modem Data Serial Number