Remote Subsonus Tag System Status Packet

This packet contains the acoustically communicated system status from the remote Subsonus Tag to the surface Subsonus unit. This packet will be generated whenever remote data is received on the local Subsonus.

Remote Subsonus Tag System Status Packet

Packet ID 106
Length 14
Read / Write Read
Field # Bytes Offset Data Type Size Description

1

0

u16

2

Device Address, see Subsonus Device Addresses

2 2

u32

4

Observer Unix Time Seconds, see Unix Time Seconds

3 6

u32

4

Observer Microseconds, see Microseconds

4 10 u32 4

Remote Subsonus Tag system status, see System Status